ND 5E / 5C
Error with Drain System. Water level not below water level sensor reset point (15 to 30 minutes after draining starts).
NF 4E / 4C
Error with Water Filling System. Filling time is over 15 minutes or no change to water level 3 to 5 minutes after water supply starts.
NF1 4E2 / 4C2
Water temperature not normal at initial time of water supply. Error with the water hose connection, thermistor or PCB.
LE1 1E / 1C
Error with Water Level Sensor. Sensor is out of range or there is loose wire connection on pressure switch or PCB terminal. When it happens, drain pump will be turned on automatically and stay on regardless of operating condition.
LE / LC / LC1
Error with Water Leaking. Water level below water level sensor signal reset point for 5 seconds or longer during Rince Cycle. When it happens, drain pump will be turned on automatically and stay on regardless of operating condition.
OE / OC
Error with OverFill. Water level is at or above the OverFill level. When it happens, water will be automatically drained until water falls below OverFill level.
dE / dC
Door is detected open while trying to be locked.
FL / dE1 / dC1
Error with Door Lock. Door fails to lock after 3 – 7 attempts.
LO
Error with Door Lock. Door fails to lock after 3 attempts.
dL
Error with Door Lock. Door open while the motor operating.
dS
Error with Door Lock. Door open while trying to be locked.
ddC
Error with Add Door open/close switch on main PCB.
dC3
Error with Add Door lock switch on main PCB. Terminal or wire connection is broken.
dc / UE / Ub / Ur
Error with Load Balance or Hall Switch. Drum not balanced or cabinet bump detected during final spin. Extremely unbalanced load or Hall Sensor error which prevents the drum from spinning faster than 140 – 400 RPM.
bE
Error with Hall Sensor. Hall Sensor signals received while motor is not operating.
3E* / 3C*
Motor won’t turn, no feedback signal from motor detected.
E3
No feedback from Hall Sensor to MICOM. Motor Locked, defective Hall Sensor or PCB.
2E / 9E* / 9C*
Voltage for motor is higher or lower than specified limit. Error with Power Supply or PCB Power Control Bus.
E2 / bC2
Button is Jammed. Any button is held for over 12 seconds or jammed.
7E
Error with Silver Care System. Silver Care Kit is running out, Silver Care PCB defective, main PCB defective or wire connection error.
8E
Error with Vibration Sensor. Error with Motor Assy (For WF203 / BFW36 only).
8E / 8C
Error with MEMS Sensor. Abnormal output (Over 4.5V or under 0.5V) from sensor is maintained for 5 seconds or longer.
8E1 / 8C1
Error with Front MEMS Sensor. Abnormal output (Over 4.5V or under 0.5V) from sensor is maintained for 5 seconds or longer.
8E2 / 8C2
Error with Rear MEMS Sensor. Abnormal output (Over 4.5V or under 0.5V) from sensor is maintained for 5 seconds or longer.
HE / HC / HC*
Error with Heater. Abnormal water temperature. Heater is open or shorted.
tE / tC / tE1 / tC1
Error with Thermistor or PBA. No feedback from Thermistor to PCB for 5 seconds or longer.
tE4 / tC4
Temperature of the Intelligent Power Modules (IPM) of the PCB is abnormal or the Thermistor of the PCB is defective.
Hr
No Heater Relay operation when there should be. PCB relay error or abnormal Thermistor.
Sr
No System Relay operation when there should be. PCB relay error.
–
Error with PCB. EEPROM Fault.
AE / AC
Error with Communication between Main PCB and Sub PCB. Wire connectors loose, Main or Sub PCB defective.
AC2
The diagnosis of the I/O Board communication check.
AE3 / AC3
Error with Communication between DR Modem and Main PCB. Wire connectors loose, Main PCB or DR Modem defective.
AE4 / AC4
Error with Communication between WIFI PCB and Main PCB. Wire connectors loose, Main PCB or WIFI PCB defective.
AE5 / AC5
Error with Communication between LCD display and Main PCB. Wire connectors loose, Main PCB or LCD PCB defective.
AE6 / AC6
Error with Communication between Main PCB and PCB Inverter. Wire connectors loose, Main PCB or PCB Inverter defective.
SF / SF1/2/3
Error with System, replace Main PCB.
PE / PC
Error with Clutch Motor. No clutch position ready signal feedback to PCB 15 seconds after the clutch motor starts.
PE1 / PC1
Error with Clutch Motor Hall Sensor. Clutch Hall Sensor signal is abnormal after the clutch position is detected.
PF
Power Failure during the Wash or Rinse Operation.
SUdS / Sd